Built-in type Spot LED lighting LED-POINT-02 is used for general and decorative interior lighting.
Product: | LED-POINT-02 |
---|---|
Current rating: | DC, 350 mA |
Power consumption: | 1 W/ 3 W |
Number of LEDs: | 1/3 |
Light Output: | up to 150 lm/W |
Luminous flux of LEDs: | up to 150/450 lm |
Radiation angles: | 170° |
luminous intensity distribution curve: | D |
Color rendering index CRI: | 80Ra |
Light color: | Warm white, cold white |
LED: | OSRAM (Germany) |
Degree of protection: | IP20 |
Lamp`s efficiency: | not less than 60% |
Temperature operating range: | from -40°C to +50°C |
Dimensions: | D82х20 |
Housing: | Metal, chrome |
Diffuser: | decorative glass with fluorescent particles |
Life time: | 100000 h. |
Warranty: | 18 month |
Electronic Light makes custom lighting products using LED at the request of the customer. You can also make the LED lighting yourself, applying special LED modules for the lightings!
If you don`t observe the polarity it is possible to get LED failure. There is a visible point On LED`s part of the negative terminal. For proper connection of the LED lighting (unit) it`s presented special connectors that are installed on lamp (unit) and the power source.
If you don`t observe the number of LEDs mounted on a specific power supply model, there is a possible failure of the source and / or light-emitting diodes. One and more LEDS can be installed in on lighting or unit. When you connect lamps (units) to a specific source, it is necessary to determine the number of LEDs in the lighting.
On the power supply CS 31350 it can be installed at least 1 and no more than 9 LEDs.
On the power supply JA-80350M it is possible to install at least 10 and not more than 24 light-emitting diodes.
When installing lightings (units) with red or yellow LEDs, the number of diodes must be increased by half, for each power supplyDo not turn on the network to 220V power supply without connected lamps (units).
In case of overheating above the permissible norm in the service term of the LEDs is to be reduced and possible failure may be occurred.
LED units must be installed with the help of thermal tape on a surface with good heat removing.